section 6
6.4 | dry contact- mute & unmute schematic
Schematic 7
Spectra i.Net
®
Sound Masking
Dry Contact – Mute & Unmute Schematic
Top View
+
Connect to dr
y
contacts to mute and
unmute masking.
J
umper
wire from
Pin #16 to Pin #20
The i.Lon
®
offers the ability to quickly mute & unmute the sound masking for the entire
system via inputs # 15 & # 19, Input: (input 1- = 15, input 1+ = 19)
Connect a jumper wire from Pin #16 to Pin #20.
Connect the digital input to a set of dry contacts to mute and unmute.
The i.Lon® oers the ability to quickly mute and unmute the sound masking for
the entire system via inputs #15 & # 19.
Connect a jumper wire from Pin #16 to Pin #20.
Connect the digital input to a set of dry contacts to mute and unmute.
-